Düzce Calibration documents absolute accuracy in your liquid transfers by calibrating all volumetric equipment—from automated pipettes to glassware used in your laboratories—using the gravimetric method in accordance with ISO 17025 standards.
Volume Calibration ; In laboratory analysis, chemical processes, and medical testing, the accuracy of liquid volumes is the most critical factor determining the reliability of results. At Rezonans Calibration, we provide volume calibration services in compliance with TS EN ISO/IEC 17025 standards for all your volumetric equipment, ranging from microliter levels to high-capacity containers.
Even the smallest volumetric deviations in your liquid transfer equipment can directly impact experimental results and production quality. Our expert team minimizes these risks using high-precision scales in controlled laboratory conditions.
Volume calibration is the process of calculating the amount of liquid contained or delivered by a device (pipettes, burettes, etc.) based on the mass of pure water with a known density (Gravimetric Method).
The benefits of regular volume calibration for your business include:
Our Rezonans Calibration laboratory provides services for all glass and plastic-based volumetric measures as well as automated devices:
| Device Group | Equipment Calibrated |
| Automated Pipettes | Single-channel, Multi-channel, and Fixed-volume Pipettes |
| Glass Laboratory Ware | Graduated Cylinders, Volumetric Flasks, Pipettes, and Burettes |
| Dispensers and Dilutors | Automated Liquid Distribution Systems |
| Pycnometers | Density Measurement Containers |
| Industrial Containers | Standard Measuring Cans and Sample Containers |
Volume calibration requires precise monitoring of variables such as ambient temperature and water density. Our process follows these steps:
Depending on the frequency of use, it is generally recommended every 6 to 12 months. For multi-channel pipettes and devices used with corrosive liquids, a 6-month interval reduces risks.
The density of the water must be known exactly. Therefore, Type 3 or Type 1 pure water in accordance with the TS EN ISO 3696 standard is strictly used in measurements.
Yes. Especially for automated pipettes, the quality and compatibility of the tips used directly affect volumetric accuracy. Performing calibration with the tips routinely used in your laboratory yields the most accurate results.
When glassware is exposed to heat (e.g., during sterilization in an autoclave), it can expand, leading to permanent deviations in the marked volume lines. This can only be detected through calibration.
Before calibration, we perform leak tests and, if necessary, conduct basic maintenance such as piston lubrication to improve the device’s performance.
Our expert team is ready to offer you a customized calibration solution.